Our Products CATEGORY - Hydrant System

Our Fire water pump sets comprise a combination of electric motor driven, diesel engine driven and electric motor driven jockey pumps that supply water to sprinkler & wet riser fire suppression systems. Fire water pumps are required to comply with standard regulations and International Codes of Practice e.g. National Fire Protection Association (NFPA). We supply fire water pumps based on client requirement, other hydrant equipment such as hydrant pillars, fire hose, fire hose reel, Cabinets, Valves and nozzles.

 

hydrant equipment
 

1. Pendent Sprinkler

pendent sprinkler

Specifications:

  • Standard and quick response with standard coveragePendent mounting
  • Temperature rating : 57°, 68°, 79°& 93°C
  • K-factor 5.6 and 4.2
  • Brass, Chrome or White/ custom color finish
  • UL Listed and FM Approved
 

2. Upright Sprinkler

upright sprinkler

Specifications

  • Standard and quick response with standard coverage
  • Upright mounting
  • Temperature rating : 57°, 68°, 79°& 93°C
  • K-factor 5.6 and 4.2
  • Brass, Chrome or White/ custom color finish
  • UL Listed and FM Approved
 

3. Horizontal Sidewall Sprinkler

horizontal sidewall sprinkler

Specifications

  • Standard and quick response with standard coverage
  • Horizontal Sidewall mounting
  • Temperature rating : 68°, 79°& 93°C
  • K-factor 5.6 and 4.2
  • Brass, Chrome or White/ custom colour finish
  • UL Listed and FM Approved
 

4. Flexible Sprinkler Drop

flexible sprinkler drop

Standards

  • Flexible Sprinkler Connections
  • Complete unit, a corrugated stainless steel flexible with nipple, reducer, Bar and brackets, which are fitted to the ceiling tile support rails to locate and secure the sprinkler in the correct position
  • Sizes: 800MM, 1000MM, 1200MM, 1500MM
  • Max Service Pressure - 12 Bar
  • Material flexible - Stainless Steel
  • Support Brackets, Inlet/Outlet Connectors and Square Bar - Mild steel, zinc plated
  • UL Listed
 

5. Deluge Valve Model H2

deludge valve model h2

Specifications

  • Fast application of water in spray, pre-action and foam system
  • Cast Steel ASTM A216 WCB construction
  • Size: 50, 80, 100, 150 & 200 mm (2", 3", 4", 6" & 8")
  • Maximum service pressure 17.5 bar (250 PSI)
  • Horizontal or Vertical installation
  • Bronze Seat
  • Flanged connection dimensions to ANSI B 16.5
  • No latch, no piston, no hinges
  • Simple yet rugged
  • Diaphragm operated with rubber to metal drip-tight positive sealing
  • Auto-reset type
  • Service without removal from line
  • Easily trimmed for actuation by manual, remote solenoid valve & with wet or dry pilot
  • Internal and external surfaces epoxy coated for extra protection
  • UL Listed
 

6. Deluge Valve Model H5

deludge valve model h5

Specifications

  • Deluge Valve Model H5
  • Fast application of water in spray and foam system
  • Nickel Aluminum Bronze BS1400 Gr AB2 construction with suitable trim
  • Size: 50, 80, 100, 150 & 200 mm (2", 3", 4", 6" & 8")
  • Maximum service pressure 17.5 bar (250 PSI)
  • Horizontal or Vertical mounting
  • Flanged connection dimensions to ANSI B 16.5
  • No latch, no piston, no hinges
  • Simple yet rugged
  • Diaphragm operated with rubber to metal drip-tight positive sealing
  • Auto-reset type
  • Service without removal from line
  • Easily trimmed for actuation by manual, remote solenoid valve & with wet or dry pilot
  • UL Listed
 

7. High Pressure Water Mist System (ZSXG)

high pressure water mist system

Description

Container Cylinder high pressure water mist fire extinguishing system is composed of water supply device, selector zonal controller valve, pressure switch, water mist nozzle, pipeline and fire alarm extinguishing controller, fire detector, acousto-optic alarm, manual control box, subarea display board, etc.

Characteristics

  • Fog drop is smaller than medium pressure system;
  • System responding time is shorter;
  • It does not need water storage tank and pond;
  • Several devices can make combination use in terms of project application and customer requirements;
  • When power is off, system can extinguish fire by mechanic emergency manual emergency